Digi-Loop Large Area, Dual Channel Hearing Loop Amplifier
Model: DL210 NET 2.0
- Network control - allows control and calibration of unit remotely with application software
- High continuous current 12 Arms (17 Apk) per output continuous
- LCD Screen with VU metering, easy one-button menu control
- DSP Audio Processing
- USB for firmware updates
The DL210 NET 2.0 hearing loop amplifier maximizes modern amplifier technology. Its network-control capability provides seamless, remote system set-up, operation, and monitoring of the induction loop system via a laptop or tablet. DSP audio processing offers flexible, powerful software control of mixing, equalization, compression, and more. Powerful Class D pulse-width amplifier maximizes the efficiency of the unit.
This assistive listening system’s design offers a dual 12 A rms loop output for dual loop or phased array configuration. A 70-100 V input connects to a distributed speaker/paging system, ensuring announcements are heard by hearing aid users.
Meet IEC 60118-4 standards on system performance when integrated into a correctly designed and installed system. The DL210 NET 2.0 is also tested to IEC Specifications 62489-1 Benchmark Standards.
- Network control - allows control and calibration of unit remotely with application software
- High continuous current 12 Arms (17 Apk) per output continuous
- LCD Screen with VU metering, easy one-button menu control
- DSP Audio Processing
- USB for firmware updates
- Input mixing, parametric equalization, compression, metal compensation, high and low-pass filters, AGC and audio delay
- Power-save mode
- Adjustable output delay for multiple amps in large venues
- Fault warning and active protection against shorted or open circuits and overheating
- Loop fault relay output
- XLR and 3-position terminal block input configurable as microphone input or line-input, balanced or unbalanced.
- Standard 2 RU, 19-inch rackmount
- Magnetic signal couples directly to devices equipped with telecoils (T-coils) such as hearing aids, cochlear implants, or optional loop receivers.
- Suitable for phased-array or dual-loop systems
- Phased-array mode automatically produces 90° phase shift in slave loop output
- Meets IEC 60118-4 system performance requirements when integrated into a correctly designed and installed system
- Test specification provided to IEC 62489-1 standard.
- Meets ADA/ADAAG guidelines
- System Includes:
- (1) DL 210 NET 2.0 DSP – Induction Loop Amplifier
- (1) WLC 004 – Line Cord (US)
- (1) IDP 009 – ADA Wall Plaque (T-Coil)
- Amplifier Type - Other
- Rackmountable - Yes
- ROHS Compliant - Yes
- Warranty - Yes
- Spec Sheet available - Yes
- Maximum Frequency Response (Bandwidth): 9 kHz
- Maximum Frequency Response (Bandwidth): 9000 Hz
- Minimum Frequency Response (Bandwidth): 45 Hz
- Minimum Frequency Response (Bandwidth): 0.05 kHz
- Certifications: UL, CE, FCC
- Communication Ports: USB, RS232
- Number of Channels: 2
- Rack Units (Height): 2
- Total Harmonic Distortion + Noise (THD+N): 1 %
- AC Voltage (Maximum): 240 Volts
- AC Voltage (Minimum): 100 Volts
- Active Power: 250 Watt
- Current Draw: 5 Amps
- Depth: 12 in
- Height: 3.50 in
- Width: 19 in
- Product Weight: 14.30 lbs
- Color: Black
- Regulatory Compliance: WEEE
- Warranty (Length/Type): 2 Year
- Operating Temperature (Maximum): 95 F
- Operating Temperature (Minimum): 32 F
- DL210 NET 2.0:
•Dimensions: 2 RU Rackmount, 19” W x 3.5” H x 12” D. Chassis is 17” W.
•Weight: 14.3 lbs (6.5 kg)
•Color: Case: Black, white and blue legends on front, white legends on back. LCD: Backlit Blue.
•Fan cooling: Variable Speed, Temperature Controlled
•Power supply: Internal, Universal 100-240 VAC, 50/60 Hz, 250 Watt. Fuse: 5 x 20 mm, 5 A, 250 V. AC power plug is IEC 320-C14.Heat output at 120 VAC: Sleep state: 100 BTU/hr; Idle state: 146 BTU/hr; Driving two loops at 12 A each: 1,040 BTU/hr
•Ethernet: (1x) RJ-45; 10-100 MBps.
•USB: (1x) standard-B. USB 1.1, 2.0 or 3.0 supported
•RS-232/Loop fault relay: (1x) DB-9 jack. RS-232: Pin 2=Tx, Pin 3=Rx, Pin 5=gnd. Loop fault relay: Pin 1=NC, Pin 4=Common, Pin 6=NO. Relay contact rating: 2.0 A at 30 VDC
•Environment: 0-35° C ( 32-95° F), 0-90% relative humdity.
•Coverage area: 31,400 sq. ft. (2,917 sq. m.) (Perimeter Loop, 1:1 aspect ratio, both outputs driven) 51,660 sq. ft. (4,800 sq. m.) (Perimeter Loop, 3:1 aspect ratio, both outputs driven)
•INPUTS
•Dante input: No. Dante input available on DL210 NET D 2.0 model only.
•Mic/Line inputs: (2x) 3-position terminal block, input impedance=1.5 kO Mic, 10 kO Line. Configurable/Accepts: Mic, Line -10 dBV, Line +4 dBu, or Line +8 dBu, balanced or unbalanced. Phantom supply (48V).
•70-100 V input: (1x) 2-position terminal block; high/speaker-level input (accepts 25 V, 70 V or 100 V) from distributed audio/paging systems
•OUTPUTS
•Line outputs: (1x) 3-position terminal block; loop-through of Mic/Line Input 1 [&] Line Input 2, +4 dBu, Balanced or Unbalanced. The line outputs mirror the audio of the loop output.
•Loop output(s): (1x) 2-position terminal block per output
•Audio output delay: Adjustable from 0 to 165 msec
•Headphone output: (1x) 1/4” stereo headphone jack, on front of unit. Monitored input or output selectable in menu
•Loop fault relay: Integrated into RS-232 DB-9 jack. Pin 1=NC, Pin 4=Common and Pin 6=NO. Contact rating: 2.0 A at 30 VDC.
•Loop output drive voltage: 33.3 Vrms (47.1 Vpk) continuous
•Rated loop output current*: 12 Arms(17 Apk) per output
•Loop resistance range: 0.5 ohms to 3.0 ohms (DC)
•Speaker output: Integrated into Loop Output A terminal block (switchable in menu). 225 Watts x 1 channel at 4O, 125 Watts x 1 channel at 8O, (Class D). Frequency response = 20 Hz-20 kHz, THD=0.07%.
•AUDIO
•Rated load: 0.5 ohms DC with 135 uH inductance
•Loop frequency response: 45 Hz to 9.0 kHz ± 2 dB (1 kHz ref.)
•Rated loop THD*: [lt]1 % at rated output current (1 kHz sine wave).
•OTHER
•Front controls: Front LCD display menu access/adjustment via control button/dial.
•Adjustable settings: Input mixing, parametric equalization, compression, metal loss compensation, high and low-pass filters, AGC and audio delay, output levels. See User Manual for adjustment range(s)
•Internal calibration tools: Test tone generator with pink noise, loop current adjustment/matching
•Other features: Save/load configuration, loop test, priority input selection with adjustable threshold, loop fault relay, open/short and thermal protection
•Network control [and] firmware: Function control and calibration by DigiLoop PC App via ethernet (RJ-45). PC App requires Windows 7 or higher. Firmware updates through USB only
•Warranty: 2 years
•Approvals: CE, UL, ULC, FCC, Industry Canada, RoHS, WEEE, CB scheme, RCM
•Standards compliance: This product is designed to meet the IEC-60118-4 standard when correctly designed, installed and commissioned. Test Specifications provided to the IEC 62489-1 standard

Advanced Sound & Communication
3817 Broadway
Kansas City, MO 64111
USA
(816) 931-9525
www.advancedsoundkc.com