SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America
Series: SMARTONLINE™
Model: SU40K
- N+1 configuration: two self-contained, redundant 20kVA power modules can be hot-swapped with the load powered if maintenance is required
- 1+1 configuration: two SU40K models connected in parallel provide fail-safe redundancy or increased capacity
- High input power factor, advanced IGBT inverter technology and Digital Signal Processor (DSP) technology produce low input Total Harmonic Distortion (THDi)
- Low THDi (less than 3%) saves installation costs by allowing 1:1 generator sizing
- Extremely efficient operation (up to 96%) saves money by lowering electricity consumption
- N+1 configuration: two self-contained, redundant 20kVA power modules can be hot-swapped with the load powered if maintenance is required
- 1+1 configuration: two SU40K models connected in parallel provide fail-safe redundancy or increased capacity
- High input power factor, advanced IGBT inverter technology and Digital Signal Processor (DSP) technology produce low input Total Harmonic Distortion (THDi)
- Low THDi (less than 3%) saves installation costs by allowing 1:1 generator sizing
- Extremely efficient operation (up to 96%) saves money by lowering electricity consumption
- True on-line, double conversion UPS with IGBT technology provides pure sine wave AC output at all times
- Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
- Removes harmonic distortion, electrical impulses, frequency variations and other hard-to-solve power problems
- 40,000VA/32,000W power capacity with 3-phase, hardwire 120/208VAC input/output connections
- Features a wide input voltage correction range: 94-150/163-260VAC
- Internal power and battery components are combined in a single small-footprint tower module. Typical half-load/full-load runtimes are 13 min./5.5 min. Battery runtime can be extended with optional stand-alone hardwired external battery modules (Models BP48
- Front panel combination LCD/LED display includes a real-time event log screen with up to 500 events listed
- Dynamic battery management screen optimizes battery function to lengthen service life and allow cold restart of the UPS
- Built-in RS-232 communication port works with included PowerAlert Software to provide shutdown commands and reporting on a single server
- Accessory slot accepts an optional internal SNMP card (Model: SNMPWEBCARD) for remote shutdowns, reboots and more
- Emergency Power Off button turns UPS output OFF and disables Bypass output
- Built-in Emergency Power Off (EPO) dry-contact interface supports remote emergency shutdown in large facilities
- Start-up service program is recommended to enhance the reliability of the installation
- Package Includes SU40K UPS System, PowerAlert Software and cabling, Parallel cable (for 1+1 operation), Instruction manual and startup checklist, Warranty information
- Warranty - Yes
- UL Rated - Yes
- Spec Sheet available - Yes
- Operating Temperature (Maximum): 104 F
- Operating Temperature (Minimum): 32 F
- UL Rated: Yes
- Depth: 33.70 in
- Height: 66.90 in
- Width: 20.50 in
- Product Weight: 1512.50 lbs
- Shipping Weight: 1690.20 lbs
- Warranty (Length/Type): 1 Year
- Output volt amp capacity: 40000 VA
- Output Watt Capacity: 32000
- Output power factor: 0.8
- Crest Factor: 3:1
- Nominal Output Voltage(s) Supported: 120/208V; 3-Phase Wye
- Frequency Compatibility: 50 / 60 Hz
- Output voltage regulation (line mode): +/- 2%
- Output voltage regulation (Battery mode): +/- 2%
- Built-in UPS output receptacles: Hardwire
- Output AC waveform (AC mode): Sine wave
- Output AC waveform (battery mode): Pure Sine wave
- Rated input current (at maximum load): 97A (per phase, on-line)
- Nominal Input Voltage(s) Supported: 120V / 208V 3 phase wye
- UPS input connection type: Hardwire
- UPS input connection description: 120/208V (3-Phase, 4 Wire, wye)
- Full Load Runtime: 5.5 min. (32kw)
- Half Load Runtime: 13 min. (16kw)
- DC system voltage: +/- 240 VDC
- Battery recharge rate (included batteries): Less than 4 hours from 10% to 90%
- Voltage regulation description: Online, double-conversion power conditioning
- Overvoltage correction: Maintains continuous operation without using battery power during overvoltages to 150/260 (3-Phase, 4-Wire, wye), reducing output within 1% of nominal
- Undervoltage correction: Maintains continuous operation without using battery power during brownout/undervoltage conditions to 94/163 (3-Phase, 4-Wire, wye)
- UPS AC suppression joule rating: 4675
- UPS AC suppression response time: Instantaneous
- EMI / RFI AC noise suppression: Yes
- AC suppression joule rating: 4675
- AC Suppression Response Time: Instantaneous
- UPS Shipping dimensions (height x width x depth): 76.2 x 28.8 x 45.5 inch
- UPS housing material: Steel
- Cooling Method: Fans
- Storage Temperature Range: -15 to +50 °C
- Relative Humidity: 0 to 95%, non-condensing
- UPS Certifications: Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances)
- RoHS: Yes
- CISCO: Yes