High-Accuracy Platinum RTD Transmitter, -328°F to 1562°F
Model: E-RTDT-1562
- Use to connect 100O platinum RTD temperature sensors to the E-2D/5D/16D.
- Accurate to within ±0.2°F (±0.1°C). If the connected RTD sensor does not support this high of accuracy, the system will revert to the accuracy of the sensor.
- Interfaces with the E-2D/5D/16D via the RJ45 sensor port. Includes 7 ft pre-wired RJ45 cable with attached coupler to extend the transmitter up to 1000 feet (328 m) using CATx cable.
- Din rail mount housing.
- Includes pre-stripped country-specific line cord with tinned strands.
Product Info
Tech Specs
Related Products
Documents
Server Environment Monitoring System RTD Sensors
RTD Temperature Sensors & Transmitters compatible with E-2D, E-5D and E-16D
For more information, visit http://www.networktechinc.com/rtd-temperature-sensor.html#sensors
- Use to connect 100O platinum RTD temperature sensors to the E-2D/5D/16D.
- Accurate to within ±0.2°F (±0.1°C). If the connected RTD sensor does not support this high of accuracy, the system will revert to the accuracy of the sensor.
- Interfaces with the E-2D/5D/16D via the RJ45 sensor port. Includes 7 ft pre-wired RJ45 cable with attached coupler to extend the transmitter up to 1000 feet (328 m) using CATx cable.
- Din rail mount housing.
- Includes pre-stripped country-specific line cord with tinned strands.
- Warranty - Yes
- Spec Sheet available - Yes
- Operating Temperature (Maximum): 55 C
- Operating Temperature (Minimum): 0 C
- Depth: 103.89 mm
- Height: 22.61 mm
- Width: 129.03 mm
- Warranty (Length/Type): Two years
- Temperature Range: -328 to 1562°F (-200 to 850°C). When used with the E-2D/5D/16D, the supported range is -89 to 738°F (-67 to 392°C. Call an NTI product consultant to have the range expanded on the ENVIROMUX system.
- Configuration: 2, 3, or 4-wire connection
- Signal Output: 4-20 mA
- Storage Temperature: -40 to 185°F (-40 to 85°C).
E-16D
- Large Enterprise Environment Monitoring System. Power: AC. Logging: 1,000 data log entries; 1,000 event log entries.
E-16D-24V
- Large Enterprise Environment Monitoring System. Power: 24VDC. Logging: 1,000 data log entries; 1,000 event log entries.
E-16D-24VDP
- Large Enterprise Environment Monitoring System. Power: Dual 24VDC. Logging: 1,000 data log entries; 1,000 event log entries.
E-16D-48V
- Large Enterprise Environment Monitoring System. Power: 48VDC. Logging: 1,000 data log entries; 1,000 event log entries.
E-16D-48VDP
- Large Enterprise Environment Monitoring System. Power: Dual 48VDC. Logging: 1,000 data log entries; 1,000 event log entries.
E-16DDP
- Large Enterprise Environment Monitoring System. Power: Dual AC. Logging: 1,000 data log entries; 1,000 event log entries.
E-16DEL
- Large Enterprise Environment Monitoring System. Power: AC. Logging: 1,200,000 data log entries; 3,000 event log entries.
E-2D
- Small Enterprise Environment Monitoring System
E-2D-24V
- Small Enterprise Environment Monitoring System, 24VDC Power
E-2D-D
- Small Enterprise Environment Monitoring System, DIN Mounted
E-2DB
- Small Enterprise Environment Monitoring System, Back-up Battery
E-2DB-D
- Small Enterprise Environment Monitoring System, Back-up Battery, DIN Mounted
E-5D
- Medium Enterprise Environment Monitoring System
E-5D-48V
- Medium Enterprise Environment Monitoring System, 48VDC Power
E-5D-D
- Medium Enterprise Environment Monitoring System, DIN Mounted
E-5D-IND48VLT
- Industrial Medium Enterprise Environment Monitoring System, 48VDC Power
E-5D-INDLT
- Industrial Medium Enterprise Environment Monitoring System
E-5DB
- Medium Enterprise Environment Monitoring System, Back-up Battery
E-5DB-D
- Medium Enterprise Environment Monitoring System, Back-up Battery, DIN Mounted
E-5DB-IND
- Industrial Medium Enterprise Environment Monitoring System for High Temperature Environments, Back-up Batter
E-RTDS-A221
- All-Purpose 100 Ohm RTD Sensor, -67°F to 221°F
E-RTDS-D240
- Duct 100 Ohm RTD Sensor, -67°F to 240°F
E-RTDS-ER230
- Rugged Encapsulated 100 Ohm RTD Sensor, -30°F to 230°F
E-RTDS-MP240
- Mini Probe 100 Ohm RTD Sensor, -67°F to 240°F
E-RTDS-PAR540-12IN
- Pipe 100 Ohm RTD Sensor with Adjustable Ring, -58°F to +540°F, 6" to 12"
E-RTDS-PAR540-2IN
- Pipe 100 Ohm RTD Sensor with Adjustable Ring, -58°F to +540°F, 1.25" to 2"
E-RTDS-PAR540-6IN
- Pipe 100 Ohm RTD Sensor with Adjustable Ring, -58°F to +540°F, 2" to 6"
E-S420MA-24V
- 4-20mA Sensor Converter
Application Note: Connect the E-RTDT-1562 Transmitter and RTD sensor to the E-2D/5D/16D
36558 kb
- Instructions
Installation Manual
679787 kb
- Instructions
Data Sheet
627492 kb
- Data Sheet
Request Quote
Thank you!
Someone will be in touch with you shortly.
Contact InSight Systems Group Pty Ltd
close

InSight Systems Group Pty Ltd
8/170 Rooks Road
Vermont, Victoria 3133
Australia
1300 369 451
www.insightsystems.com.au
Contact in regards to this product:
Network Technologies Inc (NTI)
Model: E-RTDT-1562
Request more information from a dealer near you
close