Pro AV Catalog
Manufacturers
PRODUCT CATEGORIES
Matching Keywords
Model Numbers
Request Quote
All Products
Hall-Effect Current Sensors, Solid-Core, 0.26" Loop Diameter, 10A
Model: E-AMP10-6-5
- Measures both AC and DC currents using a solid-core system. Available rated currents: 10A, 20A, and 50A. Contact an NTI product consultant for other available ratings between 10A and 50A.
- Common applications include: monitoring AC variable speed drives, static converters for DC motor drives, battery supplied applications, uninterruptible power supplies (UPS), switched mode power supplies (SMPS), electrochemical systems, and power supplies for welding applications.
- Loop diameter: 0.26" (6.5mm).
- Response time: ?1µS @ 50A/µ S, 10%-90%.
- Galvanic isolation: 2.5KV @ 50Hz, AC, 1min.
Product Info
Tech Specs
Related Products
Documents
AC & DC Monitor Hall-Effect Transducers
Hall-Effect Transducers compatible with E-ACDCLM and E-DCLM-6
Includes a 7ft 4-wire cable for connecting to the E-ACDCLM or E-DCLM-6.
- To extend the distance between the hall-effect sensor and the E-ACDCLM or E-DCLM-6, simply connect longer wires (22AWG) using the included splices.
- It is recommended to place the E-ACDCLM or E-DCLM-6 as close to the hall-effect sensor as possible. The E-ACDCLM and E-DCLM-6 can be placed up to 1000 ft away from the E-2D/5D/16D unit using CAT5/5e/6 cable.
For more information, visit http://www.networktechinc.com/hall-effect-sensors.html
- Measures both AC and DC currents using a solid-core system. Available rated currents: 10A, 20A, and 50A. Contact an NTI product consultant for other available ratings between 10A and 50A.
- Common applications include: monitoring AC variable speed drives, static converters for DC motor drives, battery supplied applications, uninterruptible power supplies (UPS), switched mode power supplies (SMPS), electrochemical systems, and power supplies for welding applications.
- Loop diameter: 0.26" (6.5mm).
- Response time: ?1µS @ 50A/µ S, 10%-90%.
- Galvanic isolation: 2.5KV @ 50Hz, AC, 1min.
- Supply voltage: ±12V, ±15V.
- Output voltage: ±4V.
- Power consumption: ?25mA.
- Comes with two 0.08" (2mm) diameter mounting holes.
- Spec Sheet available - Yes
- Spec Sheet available - Yes
- Depth: 32 mm
- Height: 24.89 mm
- Width: 24.89 mm
- Operating Temperature: -40 to 185°F (-40 to 85°C).
- Storage Temperature: -40 to 257°F (-40 to 125°C).
E-16DEL
- Large Enterprise Environment Monitoring System. Power: AC. Logging: 1,200,000 data log entries; 3,000 event log entries.
E-ACDCLM
- AC & DC Voltage & Current Monitor
E-AMP20-6-5
- Hall-Effect Current Sensors, Solid-Core, 0.26" Loop Diameter, 20A
E-AMP50-6-5
- Hall-Effect Current Sensors, Solid-Core, 0.26" Loop Diameter, 50A
E-DCLM-6
- DC Line Monitor
Data Sheet
205010 kb
- Data Sheet
Sensors & Accessories Compatible with E-2D/5D/16D
318679 kb
- Data Sheet
Request Quote
Thank you!
Someone will be in touch with you shortly.
Contact InSight Systems Group Pty Ltd
close
InSight Systems Group Pty Ltd
8/170 Rooks Road
Vermont, Victoria 3133
Australia
1300 369 451
www.insightsystems.com.au
Contact in regards to this product:
Network Technologies Inc (NTI)
Model: E-AMP10-6-5
Request more information from a dealer near you
close